3,6/6-20,3/35 kV Aluminum Conductor XLPE Medium Voltage Cables
24 type products.
3,6/6 kV XLPE INSULATED WITH ALUMINUM CONDUCTOR, SINGLE CORE MEDIUM VOLTAGE POWER CABLES
Code : YAXC7V-R (TSE), NA2XSY(VDE), 2AXSY(IEC), Al/XLPE/SC/PVC (BS)
Standarts : TS IEC 60502-2, VDE 0276
Construction : Aluminum Conductor, Inner semi-conductor, XLPE insulation, Outer Semi-Conductor, Semi-Conductor Tape, Copper Shield, Copper Helix Tape, Polyester Tape, PVC Outer Sheath
Application : Used in Under heavy operating conditions, Underground, Power centers, Switchgear, City networks, Industrial facilities, Underground and cable channel
Technical Datas : Max. Operating Temp. 90°C
Max. Short Circuit Temp. 250°C , For Max. 5 Sec
Min. Bending Radius 15*D D:Cable Overall Diameter (mm)

YAXC7V-R, NA2XSY, 2AXSY

6/10 kV XLPE INSULATED WITH ALUMINUM CONDUCTOR, SINGLE CORE MEDIUM VOLTAGE POWER CABLES
Code : YAXC7V-R (TSE), NA2XSY(VDE), 2AXSY(IEC), Al/XLPE/SC/PVC (BS)
Standarts : TS IEC 60502-2, VDE 0276
Construction : Aluminum Conductor, Inner semi-conductor, XLPE insulation, Outer Semi-Conductor, Semi-Conductor Tape, Copper Shield, Copper Helix Tape, Polyester Tape, PVC Outer Sheath
Application : Used in Under heavy operating conditions, Underground, Power centers, Switchgear, City networks, Industrial facilities, Underground and cable channel
Technical Datas : Max. Operating Temp. 90°C
Max. Short Circuit Temp. 250°C , For Max. 5 Sec
Min. Bending Radius 15*D D:Cable Overall Diameter (mm)

YAXC7V-R, NA2XSY, 2AXSY

8,7/15 kV XLPE INSULATED WITH ALUMINUM CONDUCTOR, SINGLE CORE MEDIUM VOLTAGE POWER CABLES
Code : YAXC7V-R (TSE), NA2XSY(VDE), 2AXSY(IEC), Al/XLPE/SC/PVC (BS)
Standarts : TS IEC 60502-2, VDE 0276
Construction : Aluminum Conductor, Inner semi-conductor, XLPE insulation, Outer Semi-Conductor, Semi-Conductor Tape, Copper Shield, Copper Helix Tape, Polyester Tape, PVC Outer Sheath
Application : Used in Under heavy operating conditions, Underground, Power centers, Switchgear, City networks, Industrial facilities, Underground and cable channel
Technical Datas : Max. Operating Temp. 90°C
Max. Short Circuit Temp. 250°C , For Max. 5 Sec
Min. Bending Radius 15*D D:Cable Overall Diameter (mm)

YAXC7V-R, NA2XSY, 2AXSY

12/20 kV XLPE INSULATED WITH ALUMINUM CONDUCTOR, SINGLE CORE MEDIUM VOLTAGE POWER CABLES
Code : YAXC7V-R (TSE), NA2XSY(VDE), 2AXSY(IEC), Al/XLPE/SC/PVC (BS)
Standarts : TS IEC 60502-2, VDE 0276
Construction : Aluminum Conductor, Inner semi-conductor, XLPE insulation, Outer Semi-Conductor, Semi-Conductor Tape, Copper Shield, Copper Helix Tape, Polyester Tape, PVC Outer Sheath
Application : Used in Under heavy operating conditions, Underground, Power centers, Switchgear, City networks, Industrial facilities, Underground and cable channel
Technical Datas : Max. Operating Temp. 90°C
Max. Short Circuit Temp. 250°C, For Max. 5 Sec
Min. Bending Radius 15*D D:Cable Overall Diameter (mm)

YAXC7V-R, NA2XSY, 2AXSY

18/30 kV XLPE INSULATED WITH ALUMINUM CONDUCTOR, SINGLE CORE MEDIUM VOLTAGE POWER CABLES
Code : YAXC7V-R (TSE), NA2XSY(VDE), 2AXSY(IEC), Al/XLPE/SC/PVC (BS)
Standarts : TS IEC 60502-2, VDE 0276
Construction : Aluminum Conductor, Inner semi-conductor, XLPE insulation, Outer Semi-Conductor, Semi-Conductor Tape, Copper Shield, Copper Helix Tape, Polyester Tape, PVC Outer Sheath
Application : Used in Under heavy operating conditions, Underground, Power centers, Switchgear, City networks, Industrial facilities, Underground and cable channel
Technical Datas : Max. Operating Temp. 90°C
Max. Short Circuit Temp. 250°C , For Max. 5 Sec
Min. Bending Radius 15*D D:Cable Overall Diameter (mm)

YAXC7V-R, NA2XSY, 2AXSY

20,3/35 kV XLPE INSULATED WITH ALUMINUM CONDUCTOR, SINGLE CORE MEDIUM VOLTAGE POWER CABLES
Code : YAXC7V-R (TSE), NA2XSY(VDE), 2AXSY(IEC), Al/XLPE/SC/PVC (BS)
Standarts : TS IEC 60502-2, TSE K 204, Technical Specs, VDE 0276
Construction : Aluminum Conductor, Inner semi-conductor, XLPE insulation, Outer Semi-Conductor, Semi-Conductor Tape, Copper Shield, Copper Helix Tape, Polyester Tape, PVC Outer Sheath
Application : Used in Under heavy operating conditions, Underground, Power centers, Switchgear, City networks, Industrial facilities, Underground and cable channel
Technical Datas : Max. Operating Temp. 90°C
Max. Short Circuit Temp. 250°C , For Max. 5 Sec
Min. Bending Radius 15*D D:Cable Overall Diameter (mm)

YAXC7V-R, NA2XSY, 2AXSY

3,6/6 kV XLPE INSULATED, ROUNDED ALUMINUM ROD SHIELD WITH ALUMINUM CONDUCTOR, SINGLE CORE MEDIUM VOLTAGE POWER CABLES
Code : YAXC7VY2V-R (TSE), NA2XSYR(AL)Y (VDE), Al/XLPE/SC/PVC/AWA/PVC (BS)
Standarts : TS IEC 60502-2, VDE 0276
Construction : Aluminum Conductor, Inner semi-conductor, XLPE insulation, Outer Semi-Conductor, Semi-Conductor Tape, Copper Shield, Copper Helix Tape, Polyester Tape, PVC Separator Sheath, Aluminum Rounded Rod Shield, Helix Tape, PVC Outer Sheath
Application : Used in Under heavy operating conditions, Underground, Power centers, Switchgear, City networks, Industrial facilities, Underground and cable channel
Technical Datas : Max. Operating Temp. 90°C
Max. Short Circuit Temp. 250°C, For Max. 5 Sec
Min. Bending Radius 15*D D:Cable Overall Diameter (mm)

YAXC7VY2V-R, NA2XSYR(AL)Y

6/10 kV XLPE INSULATED, ROUNDED ALUMINUM ROD SHIELD WITH ALUMINUM CONDUCTOR, SINGLE CORE MEDIUM VOLTAGE POWER CABLES
Code : YAXC7VY2V-R (TSE),NA2XSYR(AL)Y (VDE), Al/XLPE/SC/PVC/AWA/PVC (BS)
Standarts : TS IEC 60502-2, VDE 0276
Construction : Aluminum Conductor, Inner semi-conductor, XLPE insulation, Outer Semi-Conductor, Semi-Conductor Tape, Copper Shield, Copper Helix Tape, Polyester Tape, PVC Separator Sheath, Aluminum Rounded Rod Shield, Helix Tape, PVC Outer Sheath
Application : Used in Under heavy operating conditions, Underground, Power centers, Switchgear, City networks, Industrial facilities, Underground and cable channel
Technical Datas : Max. Operating Temp. 90°C
Max. Short Circuit Temp. 250°C, For Max. 5 Sec
Min. Bending Radius 15*D D:Cable Overall Diameter (mm)

YAXC7VY2V-R, NA2XSYR(AL)Y

8,7/15 kV  XLPE INSULATED, ROUNDED ALUMINUM ROD SHIELD WITH ALUMINUM CONDUCTOR, SINGLE CORE MEDIUM VOLTAGE POWER CABLES
Code : YAXC7VY2V-R (TSE),NA2XSYR(AL)Y (VDE), Al/XLPE/SC/PVC/AWA/PVC (BS)
Standarts : TS IEC 60502-2, VDE 0276
Construction : Aluminum Conductor, Inner semi-conductor, XLPE insulation, Outer Semi-Conductor, Semi-Conductor Tape, Copper Shield, Copper Helix Tape, Polyester Tape, PVC Separator Sheath, Aluminum Rounded Rod Shield, Helix Tape, PVC Outer Sheath
Application : Used in Under heavy operating conditions, Underground, Power centers, Switchgear, City networks, Industrial facilities, Underground and cable channel
Technical Datas : Max. Operating Temp. 90°C
Max. Short Circuit Temp. 250°C, For Max. 5 Sec
Min. Bending Radius 15*D D:Cable Overall Diameter (mm)

YAXC7VY2V-R, NA2XSYR(AL)Y

12/20 kV XLPE INSULATED, ROUNDED ALUMINUM ROD SHIELD WITH ALUMINUM CONDUCTOR, SINGLE CORE MEDIUM VOLTAGE POWER CABLES
Code : YAXC7VY2V-R (TSE), NA2XSYR(AL)Y (VDE), Al/XLPE/SC/PVC/AWA/PVC (BS)
Standarts : TS IEC 60502-2, VDE 0276
Construction : Aluminum Conductor, Inner semi-conductor, XLPE insulation, Outer Semi-Conductor, Semi-Conductor Tape, Copper Shield, Copper Helix Tape, Polyester Tape, PVC Separator Sheath, Aluminum Rounded Rod Shield, Helix Tape, PVC Outer Sheath
Application : Used in Under heavy operating conditions, Underground, Power centers, Switchgear, City networks, Industrial facilities, Underground and cable channel
Technical Datas : Max. Operating Temp. 90°C
Max. Short Circuit Temp. 250°C , For Max. 5 Sec
Min. Bending Radius 15*D D:Cable Overall Diameter (mm)

YAXC7VY2V-R, NA2XSYR(AL)Y

18/30 kV XLPE INSULATED, ROUNDED ALUMINUM ROD SHIELD WITH ALUMINUM CONDUCTOR, SINGLE CORE MEDIUM VOLTAGE POWER CABLES
Code : YAXC7VY2V-R (TSE),NA2XSYR(AL)Y (VDE), Al/XLPE/SC/PVC/AWA/PVC (BS)
Standarts : TS IEC 60502-2, VDE 0276
Construction : Aluminum Conductor, Inner semi-conductor, XLPE insulation, Outer Semi-Conductor, Semi-Conductor Tape, Copper Shield, Copper Helix Tape, Polyester Tape, PVC Separator Sheath, Aluminum Rounded Rod Shield, Helix Tape, PVC Outer Sheath
Application : Used in Under heavy operating conditions, Underground, Power centers, Switchgear, City networks, Industrial facilities, Underground and cable channel
Technical Datas : Max. Operating Temp. 90°C
Max. Short Circuit Temp. 250°C , For Max. 5 Sec
Min. Bending Radius 15*D D:Cable Overall Diameter (mm)

YAXC7VY2V-R, NA2XSYR(AL)Y

20,3/35 kV XLPE INSULATED, ROUNDED ALUMINUM ROD SHIELD WITH ALUMINUM CONDUCTOR, SINGLE CORE MEDIUM VOLTAGE POWER CABLES
Code : YAXC7VY2V-R (TSE),NA2XSYR(AL)Y (VDE), Al/XLPE/SC/PVC/AWA/PVC (BS)
Standarts : TS IEC 60502-2, TSE K 204, Teknik şartname, VDE 0276
Construction : Aluminum Conductor, Inner semi-conductor, XLPE insulation, Outer Semi-Conductor, Semi-Conductor Tape, Copper Shield, Copper Helix Tape, Polyester Tape, PVC Separator Sheath, Aluminum Rounded Rod Shield, Helix Tape, PVC Outer Sheath
Application : Used in Under heavy operating conditions, Underground, Power centers, Switchgear, City networks, Industrial facilities, Underground and cable channel
Technical Datas : Max. Operating Temp. 90°C
Max. Short Circuit Temp. 250°C , For Max. 5 Sec
Min. Bending Radius 15*D D:Cable Overall Diameter (mm)

YAXC7VY2V-R, NA2XSYR(AL)Y

3,6/6 kV XLPE INSULATED, FLAT STEEL ROD SHIELD WITH ALUMINUM CONDUCTOR, SINGLE CORE MEDIUM VOLTAGE POWER CABLES
Code : YAXC8VZ3V-R (TSE), NA2XSEYFGbY(VDE)
Standarts : TSE IEC 60502-2, Teknik Şartname, VDE 0276
Construction : Aluminum Conductor, Inner semi-conductor, XLPE insulation, Outer Semi-Conductor, Semi-Conductor Tape, Copper Shield , PVC Filler, PVC Separator Sheath, Galvanized Flat Steel Rod Shield, Galvanized Steel Helix Tape, PVC Outer Sheath
Application : Used in Industrial facilities, Underground cable channels
Technical Datas : Max. Operating Temp. 90°C
Max. Short Circuit Temp. 250°C , For Max. 5 Sec
Min. Bending Radius 15*D D:Cable Overall Diameter (mm)

YAXC8VZ3V-R, NA2XSEYFGbY

6/10 kV XLPE INSULATED, FLAT STEEL ROD SHIELD WITH ALUMINUM CONDUCTOR, SINGLE CORE MEDIUM VOLTAGE POWER CABLES
Code : YAXC8VZ3V-R (TSE), NA2XSEYFGbY(VDE)
Standarts : TSE IEC 60502-2, Technical Specs, VDE 0276
Construction : Aluminum Conductor, Inner semi-conductor, XLPE insulation, Outer Semi-Conductor, Semi-Conductor Tape, Copper Shield , PVC Filler, PVC Separator Sheath, Galvanized Flat Steel Rod Shield, Galvanized Steel Helix Tape, PVC Outer Sheath
Application : Used in Under heavy operating conditions, Underground, Power centers, Switchgear, City networks, Industrial facilities, Underground and cable channel.
Technical Datas : Max. Operating Temp. 90°C
Max. Short Circuit Temp. 250°C , For Max. 5 Sec
Min. Bending Radius 15*D D:Cable Overall Diameter (mm)

YAXC8VZ3V-R, NA2XSEYFGbY

8,7/15 kV XLPE INSULATED, FLAT STEEL ROD SHIELD WITH ALUMINUM CONDUCTOR, SINGLE CORE MEDIUM VOLTAGE POWER CABLES
Code : YAXC8VZ3V-R (TSE), NA2XSEYFGbY(VDE)
Standarts : TSE IEC 60502-2, Technical Specs, VDE 0276
Construction : Aluminum Conductor, Inner semi-conductor, XLPE insulation, Outer Semi-Conductor, Semi-Conductor Tape, Copper Shield , PVC Filler, PVC Separator Sheath, Galvanized Flat Steel Rod Shield, Galvanized Steel Helix Tape, PVC Outer Sheath
Application : Used in Under heavy operating conditions, Underground, Power centers, Switchgear, City networks, Industrial facilities, Underground and cable channel.
Technical Datas : Max. Operating Temp. 90°C
Max. Short Circuit Temp. 250°C , For Max. 5 Sec
Min. Bending Radius 15*D D:Cable Overall Diameter (mm)

YAXC8VZ3V-R, NA2XSEYFGbY

12/20 kV XLPE INSULATED, FLAT STEEL ROD SHIELD WITH ALUMINUM CONDUCTOR, SINGLE CORE MEDIUM VOLTAGE POWER CABLES
Code : YAXC8VZ3V-R (TSE), NA2XSEYFGbY(VDE)
Standarts : TSE IEC 60502-2, Technical Specs, VDE 0276
Construction : Aluminum Conductor, Inner semi-conductor, XLPE insulation, Outer Semi-Conductor, Semi-Conductor Tape, Copper Shield , PVC Filler, PVC Separator Sheath, Galvanized Flat Steel Rod Shield, Galvanized Steel Helix Tape, PVC Outer Sheath
Application : Used in Under heavy operating conditions, Underground, Power centers, Switchgear, City networks, Industrial facilities, Underground and cable channel.
Technical Datas : Max. Operating Temp. 90°C
Max. Short Circuit Temp. 250°C , For Max. 5 Sec
Min. Bending Radius 15*D D:Cable Overall Diameter (mm)

YAXC8VZ3V-R, NA2XSEYFGbY

18/30 kV XLPE INSULATED, FLAT STEEL ROD SHIELD WITH ALUMINUM CONDUCTOR, SINGLE CORE MEDIUM VOLTAGE POWER CABLES
Code : YAXC8VZ3V-R (TSE), NA2XSEYFGbY(VDE)
Standarts : TSE IEC 60502-2, Technical Specs, VDE 0276
Construction : Aluminum Conductor, Inner semi-conductor, XLPE insulation, Outer Semi-Conductor, Semi-Conductor Tape, Copper Shield , PVC Filler, PVC Separator Sheath, Galvanized Flat Steel Rod Shield, Galvanized Steel Helix Tape, PVC Outer Sheath
Application : Used in Under heavy operating conditions, Underground, Power centers, Switchgear, City networks, Industrial facilities, Underground and cable channel.
Technical Datas : Max. Operating Temp. 90°C
Max. Short Circuit Temp. 250°C , For Max. 5 Sec
Min. Bending Radius 15*D D:Cable Overall Diameter (mm)

YAXC8VZ3V-R, NA2XSEYFGbY

20,3/35 kV XLPE INSULATED, FLAT STEEL ROD SHIELD WITH ALUMINUM CONDUCTOR, SINGLE CORE MEDIUM VOLTAGE POWER CABLES
Code : YAXC8VZ3V-R (TSE), NA2XSEYFGbY(VDE)
Standarts : TSE IEC 60502-2, TSE K 204, Technical Specs, VDE 0276
Construction : Aluminum Conductor, Inner semi-conductor, XLPE insulation, Outer Semi-Conductor, Semi-Conductor Tape, Copper Shield , PVC Filler, PVC Separator Sheath, Galvanized Flat Steel Rod Shield, Galvanized Steel Helix Tape, PVC Outer Sheath
Application : Used in Under heavy operating conditions, Underground, Power centers, Switchgear, City networks, Industrial facilities, Underground and cable channel.
Technical Datas : Max. Operating Temp. 90°C
Max. Short Circuit Temp. 250°C , For Max. 5 Sec
Min. Bending Radius 15*D D:Cable Overall Diameter (mm)

YAXC8VZ3V-R, NA2XSEYFGbY

3,6/6 kV XLPE INSULATED, ROUNDED STEEL ROD SHIELD WITH ALUMINUM CONDUCTOR, SINGLE CORE MEDIUM VOLTAGE POWER CABLES
Code : YAXC8VZ2V-R, NA2XSEYRY
Standarts : TSE IEC 60502-2, Technical Specs, VDE 0276
Construction : Aluminum Conductor, Inner semi-conductor, XLPE insulation, Outer Semi-Conductor, Semi-Conductor Tape, Copper Shield , PVC Filler, PVC Separator Sheath, Galvanized Rounded Steel Rod Shield, Galvanized Steel Helix Tape, PVC Outer Sheath
Application : Used in Under heavy operating conditions and mechanical stres, Underground, Power centers, Switchgear, City networks, Industrial facilities, Underground and cable channel.
Technical Datas : Max. Operating Temp. 90°C
Max. Short Circuit Temp 250°C, For Max. 5 Sec
Min. Bending Radius 15*D D:Cable Overall Diameter (mm)

YAXC8VZ2V-R, NA2XSEYRY

6/10 kV XLPE INSULATED, ROUNDED STEEL ROD SHIELD WITH ALUMINUM CONDUCTOR, SINGLE CORE MEDIUM VOLTAGE POWER CABLES
Code : YAXC8VZ2V-R, NA2XSEYRY
Standarts : TSE IEC 60502-2, Technical Specs, VDE 0276
Construction : Aluminum Conductor, Inner semi-conductor, XLPE insulation, Outer Semi-Conductor, Semi-Conductor Tape, Copper Shield , PVC Filler, PVC Separator Sheath, Galvanized Rounded Steel Rod Shield, Galvanized Steel Helix Tape, PVC Outer Sheath
Application : Used in Under heavy operating conditions and mechanical stres, Underground, Power centers, Switchgear, City networks, Industrial facilities, Underground and cable channel.
Technical Datas : Max. Operating Temp. 90°C
Max. Short Circuit Temp. 250°C , For Max. 5 Sec
Min. Bending Radius 15*D D:Cable Overall Diameter (mm)

YAXC8VZ2V-R, NA2XSEYRY

8,7/15 kV   XLPE INSULATED, ROUNDED STEEL ROD SHIELD WITH ALUMINUM CONDUCTOR, SINGLE CORE MEDIUM VOLTAGE POWER CABLES
Code : YAXC8VZ2V-R, NA2XSEYRY
Standarts : TSE IEC 60502-2, Technical Specs, VDE 0276
Construction : Aluminum Conductor, Inner semi-conductor, XLPE insulation, Outer Semi-Conductor, Semi-Conductor Tape, Copper Shield , PVC Filler, PVC Separator Sheath, Galvanized Rounded Steel Rod Shield, Galvanized Steel Helix Tape, PVC Outer Sheath
Application : Used in Under heavy operating conditions and mechanical stres, Underground, Power centers, Switchgear, City networks, Industrial facilities, Underground and cable channel.
Technical Datas : Max. Operating Temp. 90°C
Max. Short Circuit Temp. 250°C , For Max. 5 Sec
Min. Bending Radius 15*D D:Cable Overall Diameter (mm)

YAXC8VZ2V-R, NA2XSEYRY

12/20 kV  XLPE INSULATED, ROUNDED STEEL ROD SHIELD WITH ALUMINUM CONDUCTOR, SINGLE CORE MEDIUM VOLTAGE POWER CABLES
Code : YAXC8VZ2V-R, NA2XSEYRY
Standarts : TSE IEC 60502-2, Technical Specs, VDE 0276
Construction : Aluminum Conductor, Inner semi-conductor, XLPE insulation, Outer Semi-Conductor, Semi-Conductor Tape, Copper Shield , PVC Filler, PVC Separator Sheath, Galvanized Rounded Steel Rod Shield, Galvanized Steel Helix Tape, PVC Outer Sheath
Application : Used in Under heavy operating conditions and mechanical stres, Underground, Power centers, Switchgear, City networks, Industrial facilities, Underground and cable channel.
Technical Datas : Max. Operating Temp. 90°C
Max. Short Circuit Temp. 250°C , For Max. 5 Sec
Min. Bending Radius 15*D D:Cable Overall Diameter (mm)

YAXC8VZ2V-R, NA2XSEYRY

18/30 kV XLPE INSULATED, ROUNDED STEEL ROD SHIELD WITH ALUMINUM CONDUCTOR, SINGLE CORE MEDIUM VOLTAGE POWER CABLES
Code : YAXC8VZ2V-R, NA2XSEYRY
Standarts : TSE IEC 60502-2, Technical Specs, VDE 0276
Construction : Aluminum Conductor, Inner semi-conductor, XLPE insulation, Outer Semi-Conductor, Semi-Conductor Tape, Copper Shield , PVC Filler, PVC Separator Sheath, Galvanized Rounded Steel Rod Shield, Galvanized Steel Helix Tape, PVC Outer Sheath
Application : Used in Under heavy operating conditions and mechanical stres, Underground, Power centers, Switchgear, City networks, Industrial facilities, Underground and cable channel.
Technical Datas : Max. Operating Temp. 90°C
Max. Short Circuit Temp. 250°C , For Max. 5 Sec
Min. Bending Radius 15*D D:Cable Overall Diameter (mm)

YAXC8VZ2V-R, NA2XSEYRY

20,3/35 kV XLPE INSULATED, ROUNDED STEEL ROD SHIELD WITH ALUMINUM CONDUCTOR, SINGLE CORE MEDIUM VOLTAGE POWER CABLES
Code : YAXC8VZ2V-R, NA2XSEYRY
Standarts : TSE IEC 60502-2, Technical Specs, VDE 0276
Construction : Aluminum Conductor, Inner semi-conductor, XLPE insulation, Outer Semi-Conductor, Semi-Conductor Tape, Copper Shield , PVC Filler, PVC Separator Sheath, Galvanized Rounded Steel Rod Shield, Galvanized Steel Helix Tape, PVC Outer Sheath
Application : Used in Under heavy operating conditions and mechanical stres, Underground, Power centers, Switchgear, City networks, Industrial facilities, Underground and cable channel.
Technical Datas : Max. Operating Temp. 90°C
Max. Short Circuit Temp 250°C , For Max. 5 Sec
Min. Bending Radius 15*D D:Cable Overall Diameter (mm)

YAXC8VZ2V-R, NA2XSEYRY