• YXV
• N2XY
0.6/1 kV XLPE INSULATED PVC SHEATHED MULTICORE WITH COPPER CONDUCTOR POWER CABLES
0.6/1 kV XLPE INSULATED, PVC SHEATHED, MULTICORE WITH COPPER CONDUCTOR POWER CABLES
Code | YXV-U, YXV-R (TSE), N2XY (VDE) |
Standarts | TS IEC 60502-1, VDE 0276 |
Construction | Copper Conductor, XLPE Insulation ,PVC Filler Sheath, PVC Outer Sheath |
Application | These cables have a low dielectric loss, used in energy networks with sudden load change,installed mainly in residential or industrial areas. May be laid outdoors, underground or in ducts. |
Technical Datas | Max. operating temperature 90 °C
Max. short circuit temperature 250 °C Min. Bending radius 12*D D: Cable overall Dia. (mm) |
- Product Description
Dimensions and Weights |
Electrical Information
|
|||||
cross-section |
Diameter |
|
Delivery reel size for 1000m cable |
Conductor DC (maks.) resistance at 20 °C (maks.) |
Current carrying capacity in | |
|
|
|||||
mm²
|
mm
|
kg/km
|
cm
|
ohm/km
|
||
2x1.5 re
|
10,5
|
150
|
80
|
12,1
|
37
|
26
|
2x2.5 re
|
11,0
|
180
|
90
|
7,41
|
49
|
36
|
2x4 re
|
12,0
|
230
|
90
|
4,61
|
64
|
49
|
2x6 re
|
13,0
|
285
|
100
|
3,08
|
79
|
63
|
2x10 rm
|
16,0
|
450
|
110
|
1,83
|
106
|
86
|
2x16 rm
|
18,0
|
600
|
120
|
1,15
|
137
|
115
|
2x25 rm
|
21,0
|
860
|
130
|
0,727
|
176
|
149
|
2x35 rm
|
23,0
|
1100
|
130
|
0,524
|
213
|
185
|
2x50 rm
|
26,0
|
1420
|
150
|
0,387
|
252
|
225
|
2x70 rm
|
30,0
|
2000
|
180
|
0,268
|
-
|
-
|
2x95 rm
|
33,0
|
2600
|
200
|
0,193
|
-
|
-
|
2x120 rm
|
37,0
|
3300
|
220
|
0,153
|
-
|
-
|
2x150 rm
|
41,0
|
4000
|
230
|
0,124
|
-
|
-
|
2x185 rm
|
46,0
|
5000
|
240
|
0,0991
|
-
|
-
|
2x240 rm
|
50,0
|
6350
|
210*
|
0,0754
|
-
|
-
|