0.6/1 kV PVC Insulated Low Voltage Power Cables
12 type products.
0.6/1 kV PVC INSULATED SINGLE CORE CABLES WITH COPPER CONDUCTOR
Code : YVV-U, YVV-R (TSE), NYY (VDE), Cu/PVC/PVC (BS)
Standarts : TS IEC 60502-1, VDE 0276
Construction : Copper conductor, PVC insulation, PVC outer sheath
Application : Preferably for installation indoors, in cable ducts and in industrial plants or switching stations underground installation with additional protection where mechanical damage is unexpected.
Technical Datas : Max. Operating temperature 70 °C
Max. Short circuit temperature <=300 mm² for 160 °C > 300 mm² for 140 °C
Min. Bending radius 15*D D:Cable outer diameter (mm)

YVV-U, YVV-R, NYY, Cu/PVC/PVC

0.6/1 kV PVC INSULATED MULTI-CORE CABLES WITH COPPER CONDUCTOR
Code : YVV-U, YVV-R (TSE), NYY (VDE), Cu/PVC/PVC (BS)
Standarts : TS IEC 60502-1, VDE 0276
Construction : Copper conductor, PVC insulation,PVC filler, PVC outer sheath
Application : Preferably for installation indoors, in cable ducts and in industrial plants or switching stations underground installation with additional protection where mechanical damage is unexpected.
Technical Datas : Max. Operating temperature 70 °C
Max. Short circuit temperature 160 °C
Min. Bending radius 12*D D:Cable outer diameter (mm)

YVV-U, YVV-R, NYY, Cu/PVC/PVC

0.6/1 kV PVC INSULATED MULTI-CORE CABLES WITH COPPER CONDUCTOR
Code : YVV-U, YVV-R (TSE), NYY (VDE), Cu/PVC/PVC (BS)
Standarts : TS IEC 60502-1, VDE 0276
Construction : Copper conductor, PVC insulation,PVC filler, PVC outer sheath
Application : Preferably for installation indoors, in cable ducts and in industrial plants or switching stations underground installation with additional protection where mechanical damage is unexpected.
Technical Datas : Max. Operating temperature 70 °C
Max. Short circuit temperature <=300 mm² for 160 °C > 300 mm² for 140 °C
Min. Bending radius 12*D D:Cable outer diameter (mm)

YVV-U, YVV-R, NYY, Cu/PVC/PVC

0.6/1 kV PVC INSULATED MULTI CORE CABLES WITH COPPER CONDUCTOR
Code : YVV-R (TSE), NYY (VDE), Cu/PVC/PVC (BS)
Standarts : TS IEC 60502-1, VDE 0276
Construction : Copper conductor, PVC insulation,PVC filler, PVC outer sheath
Application : Preferably for installation indoors, in cable ducts and in industrial plants or switching stations underground installation with additional protection where mechanical damage is unexpected.
Technical Datas : Max. Operating temperature 70 °C
Max. Short circuit temperature <=300 mm² for 160 °C > 300 mm² for 140 °C
Min. Bending radius 12*D D:Cable outer diameter (mm)

YVV-R, NYY, Cu/PVC/PVC

0.6/1 kV PVC INSULATED MULTI CORE CABLES WITH COPPER CONDUCTOR
Code : YVV-U, YVV-R (TSE), NYY (VDE), Cu/PVC/PVC (BS)
Standarts : TS IEC 60502-1, VDE 0276
Construction : Copper conductor, PVC insulation,PVC filler, PVC outer sheath
Application : Preferably for installation indoors, in cable ducts and in industrial plants or switching stations underground installation with additional protection where mechanical damage is unexpected.
Technical Datas : Max. Operating temperature 70 °C
Max, Short circuit temperature <=300 mm² for 160 °C > 300 mm² for 140 °C
Min. Bending radius 12*D D:Cable outer diameter (mm)

YVV-U, YVV-R, NYY, Cu/PVC/PVC

0.6/1 kV PVC INSULATED CABLES WITH COPPER CONDUCTOR
Code : YVV-U(TSE), NYY (VDE), Cu/PVC/PVC (BS)
Standarts : TS IEC 60502-1, VDE 0271
Construction : Copper conductor, PVC insulation,PVC filler, PVC outer sheath
Application : Indoors and outdoors, in cable ducts, underground, in power and switching stations, industrial plants, where there is no risk of mechanical damage.
Technical Datas : Max. Operating temperature 70 °C
Max. Short circuit temperature 160 °C
Min. Bending radius 12*D D:Cable outer diameter (mm)

YVV-U, NYY, Cu/PVC/PVC

0.6/1 kV PVC INSULATED MULTI-CORE CABLES CONCENTRIC COPPER CONDUCTOR SCREEN
Code : YVC7V-U,YVC7V-R (TSE),NYCY (VDE)
Standarts : TS IEC 60502-1, VDE 0276
Construction : Copper conductor, PVC insulation,PVC filler,concentric copper conductor, PVC outer sheath
Application : In indoor installations, in cable ducts, outdoor and underground for power stations, industrial plants and switching station as well as local supply systems if increased protection is necessary.
Technical Datas : Max. Operating temperature 70 °C
Max. Short circuit temperature <=300 mm² for 160 °C > 300 mm² for 140 °C
Min. Bending radius 12*D D:Cable outer diameter (mm)

YVC7V-U, YVC7V-R, NYCY

0.6/1 kV PVC INSULATED STEEL WIRE ARMOURED MULTI-CORE CABLES WITH COPPER CONDUCTOR
Code : YVZ3V-R (TSE), NYFGbY (VDE)
Standarts : TS IEC 60502-1, VDE 0271
Construction : Copper conductor, PVC insulation, PVC filler, Galvanized flat steel wire armoured, Galvanized steel tape, PVC outer sheath
Application : Installation underground,indoor, in ducts and in the open air where mechanical protection is required against higher tensile stress during installation and operation.
Technical Datas : Max. Operating temperature 70 °C
Max. Short circuit temperature <=300 mm² for 160 °C > 300 mm² for 140 °C
Min. Bending radius 12*D D:Cable outer diameter (mm)

YVZ3V-R, NYFGbY

0.6/1 kV PVC INSULATED STEEL WIRE ARMOURED MULTI-CORE CABLES WITH COPPER CONDUCTOR
Code : YVZ3V-R (TSE), NYFGbY (VDE)
Standarts : TS IEC 60502-1, VDE 0271
Construction : Copper conductor, PVC insulation, PVC filler, Galvanized flat steel wire armoured, Galvanized steel tape, PVC outer sheath
Application : Installation underground,indoor, in ducts and in the open air where mechanical protection is required against higher tensile stress during installation and operation.
Technical Datas : Max. Operating temperature 70 °C
Max. Short circuit temperature <=300 mm² for 160 °C > 300 mm² for 140 °C
Min. Bending radius 12*D D:Cable outer diameter (mm)

YVZ3V-R, NYFGbY

0.6/1 kV PVC INSULATED STEEL WIRE ARMOURED MULTI-CORE CABLES WITH COPPER CONDUCTOR
Code : YVZ3V-R (TSE), NYFGbY (VDE)
Standarts : TS IEC 60502-1, VDE 0271
Construction : Copper conductor, PVC insulation, PVC filler, Galvanized flat steel wire armoured, Galvanized steel tape, PVC outer sheath
Application : Installation underground,indoor, in ducts and in the open air where mechanical protection is required against higher tensile stress during installation and operation.
Technical Datas : Max. Operating temperature 70 °C
Max. Short circuit temperature <=300 mm² for 160 °C > 300 mm² for 140 °C
Min. Bending radius 12*D D:Cable outer diameter (mm)

YVZ3V-R, NYFGbY

0.6/1 KV XLPE INSULATED ROUND ALUMINUM WIRE ARMOURED SINGLE CORE CABLES WITH COPPER CONDUCTOR
Code : YVY2V-R (TSE), NYR(A)Y (VDE)
Standarts : TS IEC 60502-1, VDE 0271
Construction : Copper conductor, PVC insulation, PVC filler, Aluminum Round Wire Armor, PP tape, PVC outer sheath
Application : Installation underground,indoor, in ducts and in the open air where mechanical protection is required against higher tensile stress during installation and operation.
Technical Datas : Max. Operating temperature 70 °C
Max. short circuit temperature 160°C
Min. Bending radius 15*D D: Cable overall Dia. (mm)

YVY2V-R, NYR(A)Y

0.6/1 kV PVC INSULATED ROUND STEEL WIRE ARMOURED CABLES WITH COPPER CONDUCTOR
Code : YVZ2V-R (TSE), YVZ2V-U, NYRY (VDE)
Standarts : TS IEC 60502-1, VDE 0271
Construction : Copper conductor, PVC insulation, PVC filler, Galvanized round steel wire armoured, Galvanized steel tape, PVC outer sheath
Application : Installation underground,indoor, in ducts and in the open air where mechanical protection is required against higher tensile stress during installation and operation.
Technical Datas : Max. Operating temperature 70 °C
Short circuit temperature <=300 mm² for 160 °C > 300 mm² for 140 °C
Min. Bending radius 12*D D:Cable outer diameter (mm)

YVZ2V-R, YVZ2V-U, NYRY