0,6/1 kV Aluminum Conductor XLPE Low Voltage Cables
13 type products.
Code : YAXV-R, NA2XY
Standarts : TS IEC 60502-1, VDE 0276
Construction : Aluminum Conductor, XLPE insulation, PVC outer Steath
Application : These cables with very low dielectric losses are used in power plants, in the residential and industrial areas, underground internal / external and in cable ducts where there is sudden load changes.
Technical Datas : Max. Operating Temp. 90°C
Max. Short Circuit Temp. 250°C
Min. Bending Radius 15*D D:Cable Overall Diameter (mm)
Standarts : TS IEC 60502-1, VDE 0276
Construction : Aluminum Conductor, XLPE insulation, PVC outer Steath
Application : These cables with very low dielectric losses are used in power plants, in the residential and industrial areas, underground internal / external and in cable ducts where there is sudden load changes.
Technical Datas : Max. Operating Temp. 90°C
Max. Short Circuit Temp. 250°C
Min. Bending Radius 15*D D:Cable Overall Diameter (mm)
YAXV-R, NA2XY
Code : YAXV-R, NA2XY
Standarts : TS IEC 60502-1, VDE 0276
Construction : Aluminum Conductor, XLPE insulation, PVC outer Steath
Application : These cables with very low dielectric losses are used in power plants, in the residential and industrial areas, underground internal / external and in cable ducts where there is sudden load changes.
Technical Datas : Max. Operating Temp. 90°C
Max. Short Circuit Temp. 250°C
Min. Bending Radius 12*D D:Cable Overall Diameter (mm)
Standarts : TS IEC 60502-1, VDE 0276
Construction : Aluminum Conductor, XLPE insulation, PVC outer Steath
Application : These cables with very low dielectric losses are used in power plants, in the residential and industrial areas, underground internal / external and in cable ducts where there is sudden load changes.
Technical Datas : Max. Operating Temp. 90°C
Max. Short Circuit Temp. 250°C
Min. Bending Radius 12*D D:Cable Overall Diameter (mm)
YAXV-R, NA2XY
Code : YAXV-R, NA2XY
Standarts : TS IEC 60502-1, VDE 0276
Construction : Aluminum Conductor, XLPE insulation, PVC outer Steath
Application : These cables with very low dielectric losses are used in power plants, in the residential and industrial areas, underground internal / external and in cable ducts where there is sudden load changes.
Technical Datas : Max. Operating Temp. 90°C
Max. Short Circuit Temp. 250°C
Min. Bending Radius 12*D D:Cable Overall Diameter (mm)
Standarts : TS IEC 60502-1, VDE 0276
Construction : Aluminum Conductor, XLPE insulation, PVC outer Steath
Application : These cables with very low dielectric losses are used in power plants, in the residential and industrial areas, underground internal / external and in cable ducts where there is sudden load changes.
Technical Datas : Max. Operating Temp. 90°C
Max. Short Circuit Temp. 250°C
Min. Bending Radius 12*D D:Cable Overall Diameter (mm)
YAXV-R, NA2XY
Code : YAXV-R, NA2XY
Standarts : TS IEC 60502-1, VDE 0276
Construction : Aluminum Conductor, XLPE insulation, PVC outer Steath
Application : These cables with very low dielectric losses are used in power plants, in the residential and industrial areas, underground internal / external and in cable ducts where there is sudden load changes.
Technical Datas : Max. Operating Temp. 90°C
Max. Short Circuit Temp. 250°C
Min. Bending Radius 12*D D:Cable Overall Diameter (mm)
Standarts : TS IEC 60502-1, VDE 0276
Construction : Aluminum Conductor, XLPE insulation, PVC outer Steath
Application : These cables with very low dielectric losses are used in power plants, in the residential and industrial areas, underground internal / external and in cable ducts where there is sudden load changes.
Technical Datas : Max. Operating Temp. 90°C
Max. Short Circuit Temp. 250°C
Min. Bending Radius 12*D D:Cable Overall Diameter (mm)
YAXV-R, NA2XY
Code : YAXV-R, NA2XY
Standarts : TS IEC 60502-1, VDE 0276
Construction : Aluminum Conductor, XLPE insulation, PVC outer Steath
Application : These cables with very low dielectric losses are used in power plants, in the residential and industrial areas, underground internal / external and in cable ducts where there is sudden load changes.
Technical Datas : Max. Operating Temp. 90°C
Max. Short Circuit Temp. 250°C
Min. Bending Radius 12*D D:Cable Overall Diameter (mm)
Standarts : TS IEC 60502-1, VDE 0276
Construction : Aluminum Conductor, XLPE insulation, PVC outer Steath
Application : These cables with very low dielectric losses are used in power plants, in the residential and industrial areas, underground internal / external and in cable ducts where there is sudden load changes.
Technical Datas : Max. Operating Temp. 90°C
Max. Short Circuit Temp. 250°C
Min. Bending Radius 12*D D:Cable Overall Diameter (mm)
YAXV-R, NA2XY
0,6/1 kV XLPE INSULATED WITH ALUMINUM CONDUCTOR, PVC OUTER SHEATH AND FLAT STEEL SHIELD POWER CABLES
Code : YAXZ3V-R, NA2XFGBY Standarts : TS IEC 60502-1, VDE 0271
Construction : Aluminum Conductor, XLPE insulation, PVC Filler, Galvanized Flat Steel, Galvanized Steel Helix Tape, Pvc Outer Sheath
Application : Used in excessive mechanical stresses on internal-external ground and in the cable channel as Lightning and power cable.
Technical Datas : Max. Operating Temp. 90°C
Max. Short Circuit Temp. 250°C
Min. Bending Radius 12*D D:Cable Overall Diameter (mm)
YAXZ3V-R, NA2XFGBY
0,6/1 kV XLPE INSULATED WITH ALUMINUM CONDUCTOR, PVC OUTER SHEATH AND FLAT STEEL SHIELD POWER CABLES
Code : YAXZ3V-R, NA2XFGBY Standarts : TS IEC 60502-1, VDE 0271
Construction : Aluminum Conductor, XLPE insulation, PVC Filler, Galvanized Flat Steel, Galvanized Steel Helix Tape, PVC Outer Sheath
Application : Used in excessive mechanical stresses on internal-external ground and in the cable channel as Lightning and power cable.
Technical Datas : Max. Operating Temp. 90°C
Max. Short Circuit Temp. 250°C
Min. Bending Radius 12*D D:Cable Overall Diameter (mm)
YAXZ3V-R, NA2XFGBY
0,6/1 kV XLPE INSULATED WITH ALUMINUM CONDUCTOR, PVC OUTER SHEATH AND FLAT STEEL SHIELD POWER CABLES
Code : YAXZ3V-R, NA2XFGBY Standarts : TS IEC 60502-1, VDE 0271
Construction : Aluminum Conductor, XLPE insulation, PVC Filler, Galvanized Flat Steel, Galvanized Steel Helix Tape, Pvc Outer Sheath
Application : Used in excessive mechanical stresses on internal-external ground and in the cable channel as Lightning and power cable.
Technical Datas : Max. Operating Temp. 90°C
Max. Short Circuit Temp. 250°C
Min. Bending Radius 12*D D:Cable Overall Diameter (mm)
YAXZ3V-R, NA2XFGBY
Code : YAXY2V-R, NA2XR(A)Y
Standarts : TS IEC 60502-1, VDE 0271
Construction : Aluminum Conductor, XLPE insulation, PVC Filler, Round Aluminum, PP Helix Tape, Pvc Outer Sheath
Application : Used in excessive mechanical stresses on internal-external ground and in the cable channel as Lightning and power cable.
Technical Datas : Max. Operating Temp. 90°C
Max. Short Circuit Temp. 250°C
Min. Bending Radius 15*D D:Cable Overall Diameter (mm)
Standarts : TS IEC 60502-1, VDE 0271
Construction : Aluminum Conductor, XLPE insulation, PVC Filler, Round Aluminum, PP Helix Tape, Pvc Outer Sheath
Application : Used in excessive mechanical stresses on internal-external ground and in the cable channel as Lightning and power cable.
Technical Datas : Max. Operating Temp. 90°C
Max. Short Circuit Temp. 250°C
Min. Bending Radius 15*D D:Cable Overall Diameter (mm)
YAXY2V-R, NA2XR(A)Y
Code : YAXZ2V-R, NA2XRGBY
Standarts : TS IEC 60502-1, VDE 0271
Construction : Aluminum Conductor, XLPE insulation, PVC Filler, Galvanized Round Steel, Galvanized Steel Helix Tape, Pvc Outer Sheath
Application : Used in excessive mechanical stresses on internal-external ground and in the cable channel as Lightning and power cable.
Technical Datas : Max. Operating Temp. 90°C
Max. Short Circuit Temp. 250°C
Min. Bending Radius 12*D D:Cable Overall Diameter (mm)
Standarts : TS IEC 60502-1, VDE 0271
Construction : Aluminum Conductor, XLPE insulation, PVC Filler, Galvanized Round Steel, Galvanized Steel Helix Tape, Pvc Outer Sheath
Application : Used in excessive mechanical stresses on internal-external ground and in the cable channel as Lightning and power cable.
Technical Datas : Max. Operating Temp. 90°C
Max. Short Circuit Temp. 250°C
Min. Bending Radius 12*D D:Cable Overall Diameter (mm)
YAXZ2V-R, NA2XRGBY
Code : YAXZ2V-R, NA2XRGBY
Standarts : TS IEC 60502-1, VDE 0271
Construction : Aluminum Conductor, XLPE insulation, PVC Filler, Galvanized Round Steel, Galvanized Steel Helix Tape, Pvc Outer Sheath
Application : Used in excessive mechanical stresses on internal-external ground and in the cable channel as Lightning and power cable.
Technical Datas : Max. Operating Temp. 90°C
Max. Short Circuit Temp. 250°C
Min. Bending Radius 12*D D:Cable Overall Diameter (mm)
Standarts : TS IEC 60502-1, VDE 0271
Construction : Aluminum Conductor, XLPE insulation, PVC Filler, Galvanized Round Steel, Galvanized Steel Helix Tape, Pvc Outer Sheath
Application : Used in excessive mechanical stresses on internal-external ground and in the cable channel as Lightning and power cable.
Technical Datas : Max. Operating Temp. 90°C
Max. Short Circuit Temp. 250°C
Min. Bending Radius 12*D D:Cable Overall Diameter (mm)
YAXZ2V-R, NA2XRGBY
Code : YAXZ2V-R, NA2XRGBY
Standarts : TS IEC 60502-1, VDE 0271
Construction : Aluminum Conductor, XLPE insulation, PVC Filler, Galvanized Round Steel, Galvanized Steel Helix Tape, Pvc Outer Sheath
Application : Used in excessive mechanical stresses on internal-external ground and in the cable channel as Lightning and power cable.
Technical Datas : Max. Operating Temp. 90°C
Max. Short Circuit Temp. 250°C
Min. Bending Radius 12*D D:Cable Overall Diameter (mm)
Standarts : TS IEC 60502-1, VDE 0271
Construction : Aluminum Conductor, XLPE insulation, PVC Filler, Galvanized Round Steel, Galvanized Steel Helix Tape, Pvc Outer Sheath
Application : Used in excessive mechanical stresses on internal-external ground and in the cable channel as Lightning and power cable.
Technical Datas : Max. Operating Temp. 90°C
Max. Short Circuit Temp. 250°C
Min. Bending Radius 12*D D:Cable Overall Diameter (mm)
YAXZ2V-R, NA2XRGBY
Code : YAXC7V-R , NA2XCY
Standarts : TS IEC 60502-1, VDE 0276
Construction : Aluminum Conductor, XLPE insulated, PVC Filler, Copper Consantric Shield, Copper Tape Helix, PVC Outer Sheath
Application : These cables with very low dielectric losses are used in power plants, in the residential and industrial areas, underground internal / external and in cable ducts where there is sudden load changes.
Technical Datas : Max. Operating Temp. 90°C
Max. Short Circuit Temp. 250°C
Min. Bending Radius 12*D D:Cable Overall Diameter (mm)
Standarts : TS IEC 60502-1, VDE 0276
Construction : Aluminum Conductor, XLPE insulated, PVC Filler, Copper Consantric Shield, Copper Tape Helix, PVC Outer Sheath
Application : These cables with very low dielectric losses are used in power plants, in the residential and industrial areas, underground internal / external and in cable ducts where there is sudden load changes.
Technical Datas : Max. Operating Temp. 90°C
Max. Short Circuit Temp. 250°C
Min. Bending Radius 12*D D:Cable Overall Diameter (mm)
YAXC7V-R, NA2XCY