Halojen free Fire Retardant and Fire Resistant Cables
24 type products.
450/750 V HALOJEN FREE AND FLAME RETARDANT SINGLE CORE CABLES WITH COPPER CONDUCTOR
Code : H07Z1-U, H07Z1-R (TSE)
Standarts : TS EN 50525-3-31
Construction : Copper Conductor, HFFR Insulation
Application : Used in energy networks in hotels,schools, high constructions,hospitals, power plants,data processing centers, business centers where there is a risk of fire.
Technical Datas : Max. operating temperature 70 °C
Max. short circuit temperature 160 °C

H07Z1-U, H07Z1-R

450/50 V HALOJEN FREE AND FLAME RETARDANT SINGLE CORE FLEXIBLE CABLES WITH COPPER CONDUCTOR
Code : H05Z1-K, H07Z1-K (TSE)
Standarts : TS EN 50525-3-31
Construction : Flexible Copper Conductor, HFFR Insulation
Application : Used in energy networks in hotels,schools, high constructions,hospitals, power plants,data processing centers, business centers where there is a risk of fire.
Technical Datas : Max. operating temperature 70 °C
Max. short circuit temperature 160 °C

H05Z1-K, H07Z1-K

300/500 V HALOJEN FREE AND FLAME RETARDANT MULTICORE CABLES WITH COPPER CONDUCTOR
Code : NHXMH (TSE), (VDE)
Standarts : DIN VDE 0250-214, TSE K 328
Construction : Copper Conductor, XLPE Insulation, HFFR filler , HFFR Outer Sheath
Application : Used in energy networks in hotels,schools, high constructions,hospitals, power plants,data processing centers, business centers where there is a risk of fire.
Technical Datas : Max. operating temperature 90 °C
Max. short circuit temperature 250 °C
Min. Bending radius 12*D D: Cable overall Dia. (mm)

NHXMH

300/500 V HALOJEN FREE AND FLAME RETARDANT MULTICORE CABLES WITH COPPER CONDUCTOR
Code : NHMH (TSE), (VDE)
Standarts : DIN VDE 0250-215, TSE K 372
Construction : Copper Conductor, HFFR Insulation, HFFR filler , HFFR Outer Sheath
Application : Used in energy networks in hotels,schools, high constructions,hospitals, power plants,data processing centers, business centers where there is a risk of fire.
Technical Datas : Max. operating temperature 70 °C
Max. short circuit temperature 160 °C
Min. Bending radius 12*D D: Cable overall Dia. (mm)

NHMH

300/500 V HALOJEN FREE AND FLAME RETARDANT FLEXIBLE MULTICORE WITH COPPER CONDUCTOR CABLES
Code : 052XZ1-F (TSE)
Standarts : DIN VDE 0250-214, TS 13751
Construction : Flexible Copper Conductor, XLPE Insulation, HFFR filler , HFFR Outer Sheath
Application : Used in energy networks in hotels,schools, high constructions,hospitals, power plants,data processing centers, business centers where there is a risk of fire..
Technical Datas : Max. operating temperature 90 °C
Max. short circuit temperature 250 °C
Min. Bending radius 6*D D: Cable overall Dia. (mm)

052XZ1-F

0.6/1 kV XLPE INSULATED HALOJEN FREE FLAME RETARDANT SINGLE CORE WITH COPPER CONDUCTOR
Code : N2XH
Standarts : TS HD 604 S1 ,VDE 0276
Construction : Copper Conductor, XLPE Insulation, HFFR Outer Sheath
Application : Used in energy networks in hotels,schools, high constructions,hospitals, power plants,data processing centers, business centers where there is a risk of fire.
Technical Datas : Max. operating temperature 90°C
Max. short circuit temperature 250°C
Min. Bending radius 15*D D: Cable overall Dia. (mm)

N2XH

0.6/1 kV XLPE INSULATED HALOJEN FREE FLAME RETARDANT MULTICORE WITH COPPER CONDUCTOR
Code : N2XH
Standarts : TS HD 604 S1 ,VDE 0276
Construction : Copper Conductor, XLPE Insulation, HFFR filler , HFFR Outer Sheath
Application : Used in energy networks in hotels,schools, high constructions,hospitals, power plants,data processing centers, business centers where there is a risk of fire.
Technical Datas : Max. operating temperature 90°C
Max. short circuit temperature 250°C
Min. Bending radius 12*D D: Cable overall Dia. (mm)

N2XH

 0.6/1 kV XLPE INSULATED HALOJEN FREE FLAME RETARDANT MULTICORE WITH COPPER CONDUCTOR
Code : N2XH
Standarts : TS HD 604 S1 ,VDE 0276
Construction : Copper Conductor, XLPE Insulation, HFFR filler , HFFR Outer Sheath
Application : Used in energy networks in hotels,schools, high constructions,hospitals, power plants,data processing centers, business centers where there is a risk of fire.
Technical Datas : Max. operating temperature 90 °C
Max. short circuit temperature 250 °C
Min. Bending radius 12*D D: Cable overall Dia. (mm)

N2XH

0.6/1 kV XLPE INSULATED HALOJEN FREE FLAME RETARDANT MULTICORE WITH COPPER CONDUCTOR
Code : N2XH
Standarts : TS HD 604 S1 ,VDE 0276
Construction : Copper Conductor, XLPE Insulation, HFFR filler , HFFR Outer Sheath
Application : Used in energy networks in hotels,schools, high constructions,hospitals, power plants,data processing centers, business centers where there is a risk of fire.
Technical Datas : Max. operating temperature 90 °C
Max. short circuit temperature 250 °C
Min. Bending radius 12*D D: Cable overall Dia. (mm)

N2XH

0.6/1 kV XLPE INSULATED HALOJEN FREE FLAME RETARDANT MULTICORE WITH COPPER CONDUCTOR
Code : N2XH
Standarts : TS HD 604 S1 ,VDE 0276
Construction : Copper Conductor, XLPE Insulation, HFFR filler , HFFR Outer Sheath
Application : Used in energy networks in hotels,schools, high constructions,hospitals, power plants,data processing centers, business centers where there is a risk of fire.
Technical Datas : Max. operating temperature 90 °C
Max. short circuit temperature 250 °C
Min. Bending radius 12*D D: Cable overall Dia. (mm)

N2XH

0.6/1 kV XLPE INSULATED HALOJEN FREE FLAME RETARDANT WITH COPPER CONDUCTOR CONTROL CABLES
Code : N2XH
Standarts : TS HD 604 S1 ,VDE 0276
Construction : Copper Conductor, XLPE Insulation, HFFR filler , HFFR Outer Sheath
Application : Used in energy networks in hotels,schools, high constructions,hospitals, power plants,data processing centers, business centers where there is a risk of fire.
Technical Datas : Max. operating temperature 90 °C
Max. short circuit temperature 250 °C
Min. Bending radius 12*D D: Cable overall Dia. (mm)

N2XH

0.6/1 kV XLPE INSULATED HALOJEN FREE FLAME RETARDANT CONCENTRIC WIRE SCREENED WITH COPPER CONDUCTOR POWER CABLES
Code : N2XCH
Standarts : TS HD 604 S1 ,VDE 0276
Construction : Copper Conductor, XLPE Insulation ,HFFR Filler, Copper wires screen, Copper tape,HFFR Outer Sheath
Application : Used in energy networks in hotels,schools, high constructions,hospitals, power plants,data processing centers, business centers where there is a risk of fire.
Technical Datas : Max. operating temperature 90 °C
Max. short circuit temperature 250 °C
Min. Bending radius 12*D D: Cable overall Dia. (mm)

N2XCH

0.6/1 kV XLPE INSULATED HALOJEN FREE FLAME RETARDANT FLAT STEEL WIRE ARMOURED WITH COPPER CONDUCTOR POWER CABLES
Code : YXZ3Z1 (N2XFGBH), CU / XLPE /SWA / LSF
Standarts : TS IEC 60502-1
Construction : Copper Conductor, XLPE Insulation ,HFFR Filler,Galvanized flat steel wire,Galvanized steel tape,HFFR Outer Sheath
Application : These cables have a low dielectric loss, coupled with mechanical resistance are mainly used in energy networks with sudden load change residential or industrial areas.Can be laid outdoors,undergrounds and in areas where sudden mechanical stresses are expected.
Technical Datas : Max. operating temperature 90 °C
Max. short circuit temperature 250 °C
Min. Bending radius 12*D D: Cable overall Dia. (mm)

N2XFGBH, CU/XLPE/SWA/LSF

0.6/1 kV XLPE INSULATED HALOJEN FREE FLAME RETARDANT FLAT STEEL WIRE ARMOURED WITH COPPER CONDUCTOR POWER CABLES
Code : YXZ3Z1 (N2XFGBH), CU / XLPE /SWA / LSF
Standarts : TS IEC 60502-1
Construction : Copper Conductor, XLPE Insulation ,HFFR Filler,Galvanized flat steel wire,Galvanized steel tape,HFFR Outer Sheath
Application : These cables have a low dielectric loss, coupled with mechanical resistance are mainly used in energy networks with sudden load change residential or industrial areas.Can be laid outdoors,undergrounds and in areas where sudden mechanical stresses are expected.
Technical Datas : Max. operating temperature 90 °C
Max. short circuit temperature 250 °C
Min. Bending radius 12*D D: Cable overall Dia. (mm)

N2XFGBH, CU/XLPE/SWA/LSF

0.6/1 kV XLPE INSULATED HALOJEN FREE FLAME RETARDANT  ROUND STEEL WIRE ARMOURED WITH COPPER CONDUCTOR POWER CABLES
Code : N2XRH
Standarts : TSE K 339
Construction : Copper Conductor, XLPE Insulation ,HFFR Filler,Galvanized round steel wire,Galvanized steel tape,HFFR Outer Sheath
Application : These cables have a low dielectric loss, coupled with mechanical resistance are mainly used in energy networks with sudden load change residential or industrial areas.Can be laid outdoors,undergrounds and in areas where sudden mechanical stresses are expected.
Technical Datas : Max. operating temperature 90 °C
Max. short circuit temperature 250 °C
Min. Bending radius 12*D D: Cable overall Dia. (mm)

N2XRH

0.6/1 kV XLPE INSULATED HALOJEN FREE FLAME RETARDANT  ROUND STEEL WIRE ARMOURED WITH COPPER CONDUCTOR POWER CABLES
Code : N2XRH
Standarts : TSE K 339
Construction : Copper Conductor, XLPE Insulation ,HFFR Filler,Galvanized round steel wire,Galvanized steel tape,HFFR Outer Sheath
Application : These cables have a low dielectric loss, coupled with mechanical resistance are mainly used in energy networks with sudden load change residential or industrial areas.Can be laid outdoors,undergrounds and in areas where sudden mechanical stresses are expected.
Technical Datas : Max. operating temperature 90 °C
Max. short circuit temperature 250 °C
Min. Bending radius 12*D D: Cable overall Dia. (mm)

N2XRH

0.6/1 kV XLPE INSULATED HALOJEN FREE FLAME RETARDANT  ROUND STEEL WIRE ARMOURED WITH COPPER CONDUCTOR POWER CABLES
Code : N2XRH
Standarts : TSE K 339
Construction : Copper Conductor, XLPE Insulation ,HFFR Filler,Galvanized round steel wire,Galvanized steel tape,HFFR Outer Sheath
Application : These cables have a low dielectric loss, coupled with mechanical resistance are mainly used in energy networks with sudden load change residential or industrial areas.Can be laid outdoors,undergrounds and in areas where sudden mechanical stresses are expected.
Technical Datas : Max. operating temperature 90 °C
Max. short circuit temperature 250 °C
Min. Bending radius 12*D D: Cable overall Dia. (mm)

N2XRH

0.6/1 kV XLPE INSULATED HALOJEN FREE FIRE RESISTANT SINGLE CORE WITH COPPER CONDUCTOR POWER SECURITY CABLES
Code : N2XH FE 180
Standarts : TS HD 604 S1 , DIN - VDE 0276-604
Construction : Copper Conductor, Mica Tape , XLPE Insulation , HFFR Outer Sheath
Application : Used in energy networks in refineries,hotels,schools, mines, tunnels,high constructions,hospitals, power plants,data processing centers, business centers where there is a risk of fire.
Technical Datas : Max. operating temperature 90 °C
Max. short circuit temperature 250 °C
Min. Bending radius 15*D D: Cable overall Dia. (mm)

N2XH FE 180

0.6/1 kV XLPE INSULATED HALOJEN FREE FIRE RESISTANT MULTI CORE WITH COPPER CONDUCTOR POWER SECURITY CABLES
Code : N2XH FE 180
Standarts : TS HD 604 S1 , DIN - VDE 0276-604
Construction : Copper Conductor, Mica Tape , XLPE Insulation , HFFR Filler , HFFR Outer Sheath
Application : Used in energy networks in refineries,hotels,schools, mines, tunnels,high constructions,hospitals, power plants,data processing centers, business centers where there is a risk of fire.
Technical Datas : Max. operating temperature 90 °C
Max. short circuit temperature 250 °C
Min. Bending radius 12*D D: Cable overall Dia. (mm)

N2XH FE 180

0.6/1 kV XLPE INSULATED HALOJEN FREE FIRE RESISTANT MULTI CORE WITH COPPER CONDUCTOR POWER SECURITY CABLES
Code : N2XH FE 180
Standarts : TS HD 604 S1 , DIN - VDE 0276-604
Construction : Copper Conductor, Mica Tape , XLPE Insulation , HFFR Filler , HFFR Outer Sheath
Application : Used in energy networks in refineries,hotels,schools, mines, tunnels,high constructions,hospitals, power plants,data processing centers, business centers where there is a risk of fire.
Technical Datas : Max. operating temperature 90 °C
Max. short circuit temperature 250 °C
Min. Bending radius 12*D D: Cable overall Dia. (mm)

N2XH FE 180

0.6/1 kV XLPE INSULATED HALOJEN FREE FIRE RESISTANT MULTI CORE WITH COPPER CONDUCTOR POWER SECURITY CABLES
Code : N2XH FE 180
Standarts : TS HD 604 S1 , DIN - VDE 0276-604
Construction : Copper Conductor, Mica Tape , XLPE Insulation , HFFR Filler , HFFR Outer Sheath
Application : Used in energy networks in refineries,hotels,schools, mines, tunnels,high constructions,hospitals, power plants,data processing centers, business centers where there is a risk of fire.
Technical Datas : Max. operating temperature 90 °C
Max. short circuit temperature 250 °C
Min. Bending radius 12*D D: Cable overall Dia. (mm)

N2XH FE 180

0.6/1 kV XLPE INSULATED HALOJEN FREE FIRE RESISTANT MULTI CORE WITH COPPER CONDUCTOR POWER SECURITY CABLES
Code : N2XH FE 180
Standarts : TS HD 604 S1 , DIN - VDE 0276-604
Construction : Copper Conductor, Mica Tape , XLPE Insulation , HFFR Filler , HFFR Outer Sheath
Application : Used in energy networks in refineries,hotels,schools, mines, tunnels,high constructions,hospitals, power plants,data processing centers, business centers where there is a risk of fire.
Technical Datas : Max. operating temperature 90 °C
Max. short circuit temperature 250 °C
Min. Bending radius 12*D D: Cable overall Dia. (mm)

N2XH FE 180

0.6/1 KV XLPE INSULATED HFFR OUTER SHEATH HALOJEN FREE FIRE RESISTANT MULTI CORE WITH COPPER CONDUCTOR POWER SECURITY CABLES
Code : N2XH FE 180
Standarts : TS HD 604 S1 , DIN - VDE 0276
Construction : Copper Conductor, Mica Tape , XLPE Insulation , HFFR Filler, HFFR Outer Sheath
Application : Used in energy networks in refineries,hotels,schools, mines, tunnels,high constructions,hospitals, power plants,data processing centers, business centers where there is a risk of fire.
Technical Datas : Max. operating temperature 90 °C
Max. short circuit temperature 250 °C
Min. Bending radius 12*D D: Cable overall Dia. (mm)

N2XH FE 180

0.6/1 kV XLPE INSULATED AND HFFR SHEATHED HALOJEN FREE FIRE RESISTANT WITH COPPER CONDUCTOR SECURITY CONTROL CABLES
Code : N2XCH FE 180
Standarts : TS HD 604 S1 , DIN - VDE 0276-604
Construction : Copper Conductor, Mica Tape , XLPE Insulation , HFFR Filler , Copper wires screen , Copper tape , HFFR Outer Sheath
Application : Used in energy networks in refineries,hotels,schools, mines, tunnels,high constructions,hospitals, power plants,data processing centers, business centers where there is a risk of fire.
Technical Datas : Max. operating temperature 90 °C
Max. short circuit temperature 250 °C
Min. Bending radius 12*D D: Cable overall Dia. (mm)

N2XCH FE 180